![]() Synergy H1 supports the reading of 6-, 12-, 24-, 48-, 96-, and 384-well microplates withġ28 x 86 mm geometry as well as the Take3 and Take3 Trio Micro-Volume Plate. Modes, is supported to ensure that reagents are thoroughly mixed prior to reading. Internal plate shaking, with both linear and orbital The Synergy H1 has top and bottom incubation from 4☌ over ambient to 45☌, controlled Internal plate shaking is supported to ensure that reagents are properly mixed prior to reading. You can also use the monochromator optics for The Synergy HT has a 4-Zone temperature control from 4☌ over ambient to 50☌ and supports the reading of 6-, 12-, 24-, 48-, 96-, and 384-well microplates with standard 128 x 86 mm geometry. For luminescence reads, the Synergy H1 has a direct-to-PMTĬhannel (no filtering, white light only). Note: Use of microplates other than those listed here can result in positioning errors during program execution. Available read methods are endpoint, area scan, spectral scanning, and The Synergy H1 supports the reading of 6-, 12-, 24-, 48-, 96-, and 384-well microplates with 128 x 86 mm geometry as well as the Take3 and Take3 Trio Micro-Volume Plate. The monochromator provides wavelength selection from 230–999 nm in 1. Synergy LX User Manual BioTek Instruments, Inc. For each well, its Standard Deviation should be less than its Allowed Deviation. Luminescence is measured throughĪn empty filter position in the filter cube filters can be used if light filtering is necessary. For each well in columns 1 and 2, calculate the Allowed Deviation using the Repeatability specification for a 96-well plate (Mean OD x 0.01 + 0.010). The BioTek Epoch With Synergy H1 Microplate Reader can read in Absorbance (UV/Vis), Full light Luminescence and top and bottom Fluorescence Intensity. Protocol, the filter cube must contain polarizing filters. This robust multimode plate reader uses quadruple grating optics allowing for excitation and emission wavelength to be stepped in 1 nm increments. Specificity and a photomultiplier tube (PMT) detector. 96-well and 384-well plate, sweep read speed 01 OD: ☒ ☐. Xenon flash light source, along with interference filters and dichroic mirrors for wavelength Manuals and User Guides for Biotek Synergy H1. Manuals Brands Biotek Manuals Card Reader Synergy H1 Biotek Synergy H1 Manuals. The filterbased system can perform fluorescence and luminescence reads. View online or download Biotek Synergy H1 Operators Manual, Instructions For Use Manual. The Synergy H1 can perform reads using a filter cube or a monochromator. Depending on the model,ĭetection modes include fluorescence intensity (FI), fluorescence polarization (FP), timeresolved fluorescence (TRF), luminescence, and UV-visible absorbance. The Synergy Hybrid H1MF MultiMode reader has the full suite of capabilities including end point or kinetic scans and is compatible with the Take3 Plate for nucleic acid quantification. The Synergy H1 is a hybrid multi-mode microplate reader. Can perform analysis across the UV and visible spectrum in addition to bioluminescence assays.
0 Comments
Leave a Reply. |
Details
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |